MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据
MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据
MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据
MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据
MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据
MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据

型号:MAC090C-O-KD-1-B/110-A-O/-100625/S001

类别:Indramat

联系人:陈柳铭

手机:15579209656

电话:15579209656

Q Q:3136378118

邮箱:3136378118@qq.com

地址:江西省九江市瑞昌市东益路23号赛湖农商城401号


在线咨询


MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001
为每个电机/驱动器文件指定了环境和安装条件选择列表。请参阅文件“ECODRIVE Servodrives DKC with MKD-选择列表-选择列表适用于给定的环境和安装条件(见图4-9)。对于不同的条件,根据图表(见图4-8)减少短期工作扭矩. 如果同时出现偏离环境温度和更高安装高度的情况,则必须将两个荷载系数相乘。DG0200.fh5安装标高较高的荷载荷载系数环境温度°C 1000 2000 3000 4000 5000 0,6 0,8 1 0,6 0,8 1 0 40 45 50 55 0安装海拔高度米安装标高较高的荷载系数荷载图4-8:荷载利用率作为一个值取决于环境温度和安装海拔高度Symbol+55内部鼓风机冷却塔,高°C TUM°C+0+45 TL°C-30+85 m 1000%95 g/m 25 3 IP20,符合EN 60529=DIN VDE 0470-1-1992(IEC 529-1989)控制柜中的固定使用m kg 4.4 TB0204。fh5装置非导电污垢污染,无冷凝MDN和MKB的选择数据中所示的值,在+45至+55°C的范围内,每升高一°C,下降2%。名称环境和安装条件冷却功率段的大允许环境温度(标称数据减少)允许环境温度(标称数据存储和运输)大安装标高(标称数据大允许相对湿度大允许湿度)污染防护等级重量
MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据 MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据 MAC090C-O-KD-1-​B/110-A-O/-1006​25/S001说明数据
Ambient and installation conditions Selection lists are specified for each motor/drive documentation. Please refer to the documentation "ECODRIVE Servodrives DKC with MKD - Selection Lists - The selection lists apply within the given ambient and installation conditions (see Fig. 4-9). For different conditions, the short-term operating torque is reduced according to the diagrams (see Fig. 4-8). If deviating ambient temperatures and higher installation altitudes occur simultaneously, both load factors must be multiplied. DG0200.fh5 Load with higher installation elevations Load factor Ambient temperature in °C 1000 2000 3000 4000 5000 0,6 0,8 1 0,6 0,8 1 0 40 45 50 55 0 Installation altitude meters above sea level Load factor Load with higher ambient temperatures Fig. 4-8: Load utilization as a value dependent upon ambient temperature and installation altitude Symbol +55 internal blower cooling TUM,MAX °C TUM °C +0...+45 TL °C -30...+85 m 1000 % 95 g/m 25 3 IP20, as per EN 60529 = DIN VDE 0470-1-1992 (IEC 529-1989) stationary use in control cabinets m kg 4.4 TB0204.fh5 Unit Non-conductive dirt contamination, no condensation The values indicated in the selection data for MDN and MKB, drop in the range of +45 to +55°C by 2% per °C of rise in temperature. Designation Ambient and installation conditions Cooling the power section Max. permissible ambient temperature with reduced nominal data Permissible ambient temperature with nominal data Storage and transport temperature Max. installation elevation with nominal data Max. permissible relative humidity Max. permissible absolute humidity Degree of contamination Protection category Weight