产品展示
联系我们
联系人:陈柳铭
手机:15579209656
电话:
Q Q:3136378118
邮箱:3136378118@qq.com
地址:江西省九江市瑞昌市东益路23号赛湖农商城401号
Series S200 S200 M S200 P SN 201 L SN 201 SN 201 M S 280 S 280 UC S 290 S800S S800N S800C Characteristics B, C, D, K, Z B, C, D, K, Z B, C, D, K, Z B, C B, C, D B, C B, C B, K, Z K, Z C. D, K B, C, D K KM UCB UCK B, C, D B, C, D, K Rated current [A] 0.5 ≤ In ≤ 63 0.5 ≤ In ≤ 63 0.2 ≤ In ≤ 25 32 ≤ In ≤ 40 50 ≤ In ≤ 63 2 ≤ In ≤ 40 2 ≤ In ≤ 40 2 ≤ In ≤ 40 80 ≤ In ≤ 100 0.2 ≤ In ≤ 40 50 ≤ In ≤ 63 80 ≤ In ≤ 125 10 ≤ In ≤ 125 10 ≤ In ≤ 125 20 ≤ In ≤ 80 10 ≤ In ≤ 125 10 ≤ In ≤ 125 10 ≤ In ≤ 125 10 ≤ In ≤ 125 Breaking capacity [kA] Reference standard Nr. poles Ue [V] IEC 23-3/EN 60898 Icn 230/400 6 10 25 15 15 4.5 6 10 6 10 25 20 15 IEC/EN 60947-2 Icu 1, 1P+N 133 20 252 40 25 25 10 15 20 15 10 6 230 10 152 25 15 15 6 10 10 6 6 4.5 20 (15)3 50 50 50 36 2, 3, 4 230 20 252 40 25 25 10 10 6 25 50 50 50 36 25 400 10 152 25 15 15 6 6 4.5 20 (15)3 50 50 50 36 25 2, 3, 4 500 154 154 154 104 25 690 64 64 64 4.5 Ics 1, 1P+N 133 15 18.72 20 18.7 18.7 6 10 10 15 7.5 6 230 7.5 11.22 12.5 11.2 7.5 4.5 6 7.5 6 6 4.5 10 (7.5)3 40 40 40 30 18 2, 3, 4 230 151 18.72 20 18.7 18.7 10 7.5 6 12.5 40 40 40 30 18 400 7.5 11.22 12.5 11.2 7.5 6 6 4.5 10 (7.5)3 40 40 40 30 18 2, 3, 4 500 114 114 114 84 690 44 44 44 3 IEC/EN 60947-2 Direct cuttent T=I/R≤5ms for all series, except S280 UC and S800-UC whwre T=I/R<15ms Icu 1, 1P+N 24 20 60 10 10 15 10 10 10 15 15 10 25 125 6 4.5 30 30 30 250 50 50 20 10 2 48 20 125 10 10 15 10 10 10 15 15 10 250 6 4.5 30 30 30 20 10 500 50 50 600 800 3, 4 375 305 305 305 305 305 205 105 500 306 306 306 306 306 206 106 750 50 50 1000 1200 Ics 1, 1P+N 24 20 60 10 10 15 10 10 10 15 15 10 12.5 125 6 4.5 30 30 30 20 10 250 50 50 2 48 20 125 10 10 15 10 10 10 15 15 10 250 6 4.5 30 30 30 20 10 500 50 50 600 800 3, 4 375 305 305 305 305 305 205 105 500 306 306 306 306 306 206 106 750 50 50 Pro M compact miniature circuit-breakers The following table shows an overview of the MCBs, for further details please refer to the technical catalogue. 1 Only up to 40 A; 10 kA up to 50/63 A 2 < 50 A 3 Only for D characteristic 4 Values are not for all rated currents 5 3 poles 6 4 poles
Series S200 S200 M S200 P SN 201 L SN 201 SN 201 M S 280 S 280 UC S 290 S800S S800N S800C Characteristics B, C, D, K, Z B, C, D, K, Z B, C, D, K, Z B, C B, C, D B, C B, C B, K, Z K, Z C. D, K B, C, D K KM UCB UCK B, C, D B, C, D, K Rated current [A] 0.5 ≤ In ≤ 63 0.5 ≤ In ≤ 63 0.2 ≤ In ≤ 25 32 ≤ In ≤ 40 50 ≤ In ≤ 63 2 ≤ In ≤ 40 2 ≤ In ≤ 40 2 ≤ In ≤ 40 80 ≤ In ≤ 100 0.2 ≤ In ≤ 40 50 ≤ In ≤ 63 80 ≤ In ≤ 125 10 ≤ In ≤ 125 10 ≤ In ≤ 125 20 ≤ In ≤ 80 10 ≤ In ≤ 125 10 ≤ In ≤ 125 10 ≤ In ≤ 125 10 ≤ In ≤ 125 Breaking capacity [kA] Reference standard Nr. poles Ue [V] IEC 23-3/EN 60898 Icn 230/400 6 10 25 15 15 4.5 6 10 6 10 25 20 15 IEC/EN 60947-2 Icu 1, 1P+N 133 20 252 40 25 25 10 15 20 15 10 6 230 10 152 25 15 15 6 10 10 6 6 4.5 20 (15)3 50 50 50 36 2, 3, 4 230 20 252 40 25 25 10 10 6 25 50 50 50 36 25 400 10 152 25 15 15 6 6 4.5 20 (15)3 50 50 50 36 25 2, 3, 4 500 154 154 154 104 25 690 64 64 64 4.5 Ics 1, 1P+N 133 15 18.72 20 18.7 18.7 6 10 10 15 7.5 6 230 7.5 11.22 12.5 11.2 7.5 4.5 6 7.5 6 6 4.5 10 (7.5)3 40 40 40 30 18 2, 3, 4 230 151 18.72 20 18.7 18.7 10 7.5 6 12.5 40 40 40 30 18 400 7.5 11.22 12.5 11.2 7.5 6 6 4.5 10 (7.5)3 40 40 40 30 18 2, 3, 4 500 114 114 114 84 690 44 44 44 3 IEC/EN 60947-2 Direct cuttent T=I/R≤5ms for all series, except S280 UC and S800-UC whwre T=I/R<15ms Icu 1, 1P+N 24 20 60 10 10 15 10 10 10 15 15 10 25 125 6 4.5 30 30 30 250 50 50 20 10 2 48 20 125 10 10 15 10 10 10 15 15 10 250 6 4.5 30 30 30 20 10 500 50 50 600 800 3, 4 375 305 305 305 305 305 205 105 500 306 306 306 306 306 206 106 750 50 50 1000 1200 Ics 1, 1P+N 24 20 60 10 10 15 10 10 10 15 15 10 12.5 125 6 4.5 30 30 30 20 10 250 50 50 2 48 20 125 10 10 15 10 10 10 15 15 10 250 6 4.5 30 30 30 20 10 500 50 50 600 800 3, 4 375 305 305 305 305 305 205 105 500 306 306 306 306 306 206 106 750 50 50 Pro M compact miniature circuit-breakers The following table shows an overview of the MCBs, for further details please refer to the technical catalogue. 1 Only up to 40 A; 10 kA up to 50/63 A 2 < 50 A 3 Only for D characteristic 4 Values are not for all rated currents 5 3 poles 6 4 poles
相关产品